Welcome to Racetronix
Welcome to Racetronix  |  All prices indicated are in USD($)  905-477-7014  |   Help   |  Catalogs  |  About Us

Relay - 630-ISO Sealed SPDT 12V 40/30A *

Item #: VF4-65F11-S01  MPN : 9-1393305-5
This is an obsolete Item

VF4-65F11-S01 - Tyco Weatherproof 630-ISO Relay SPDT 12V 40/30A

(Used in most Racetronix harnesses manufactured in 2008 and earlier) FEATURES:

  • Shrouded plastic dust cover, steel mounting bracket
  • Supression resistor = safe for use with solid-state drivers
  • ELV compliant
  • Shrouded: protection class IP67 to IEC 529 (EN 60 529) if used with special connector
  • Limiting continuous current 40 A
  • Pin assignment according to ISO 7588 part 1
  • Plug-in terminals
COIL DATA:
  • Voltage DC: 12
  • Nominal Coil Resistance: 90 Ohms +/- 10%
  • Suppression Resistor: 680 Ohms, 1/2 Watt
  • Combined Resistance Ohms: 79.5
  • Must Release Voltage 1.2
  • Allowable Overdrive Voltage: 20.2 @ 20.2 °C, 15.7 @ 85 °C
  • Nominal power consumption: 1.6 Watts
  • Operate time at nominal voltage: Typ. 7 ms
  • Release time at nominal voltage: Typ. 2 ms
  • Ambient temperature range: –40 to +125°C
CONTACT DATA:
  • Configuartion: S.P.D.T. 4-Terminal (1 Form C)
  • Material: Silver tin oxide (AgNi0.15)
  • Limiting continuous current NC / NO
  • 23°C 45/60 Amps
  • 85°C 30/40 Amps
  • 125°C 12/17 Amps
  • Voltage drop (initial)
  • NO contact: Typ. 60 mV, 200 mV max. at 40 A
  • NC contact: Typ. 60 mV, 250 mV max. at 30 A
  • Max. switching current (1) NC/NO
  • On (2) 45/120 Amps
  • Off 40 / 60 Amps

Terminals:Quick connect terminals similar to ISO 8092-1, coil and load 6.3 x 0.8 mm; surfaces tin plated

Life Expectancy (Minimum operations):
  • Mechanical endurance (without load): Typ. 10^6 operations
  • Electrical endurance: > 1 x 1^5 operations @ 40 A, 13.5 V (NO contact), > 1 x 1^5 operations 30 A, 13.5 V (NC contact)

1) The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V or 27 V for 24 V load voltages.
2) For a load current duration of maximum 3 s for a make/break ratio of 1:10.

For more detailed info please view the manufacturer's technical brochure by clicking <HERE>