Welcome to Racetronix
Welcome to Racetronix  |  All prices indicated are in USD($)  905-477-7014  |   Help   |  Catalogs  |  About Us

Fuel Pump Wiring Kit, C44 Corvette RXP

Item #: FPWK-043W

Your Starting Price: $

Original Price: $208.12

Quick Overview

  • Replaces every wire between the hanger and the pump - connector, bulkhead, in-tank harness and grounds
  • 10 gauge relay-switched feed straight from the battery; the factory pump wire becomes a trigger only
  • Two grounds in parallel - high-current return through the hanger brass bolt plus a low-current bulkhead ground
  • 600V PTFE/ETFE in-tank wiring and a sealed fuel-safe bulkhead - no splices or solder inside the tank
  • Includes the 4-way to 3-way adapter for 1984-1988 cars; fits Walbro 255/350 and Racetronix RXP pumps

Show More
 
 
 In Stock & Ready to Ship

Fuel Pump Wiring Kit, C44 Corvette RXP


C4 Corvette Fuel Pump Wiring Kit — RXP Pump Connector

A dedicated high-current pump circuit up front, and all-new wiring from the hanger to the pump. For 1984–1988 Corvette with an aftermarket pump.

Kit FPWK-043W  |  FPWH-044HD  |  FPAH-043  |  IPH-3W12  |  BCA-4W  |  ITWH-042

Most fuel pump "hotwire" kits stop at the tank. They run a relay and a heavy feed to the rear of the car, then hand the current back to the same factory hanger connector, the same hanger wiring and the same pump leads that were the problem in the first place. The bottleneck simply moves.

This kit is built in two halves, and it treats them differently. Forward of the hanger it adds a new circuit alongside the factory one: a 10 gauge fused feed taken straight from the battery and switched by a heavy-duty relay. The factory pump circuit stays completely intact and must remain functional, because that is what triggers the relay. Your car keeps full control of the pump, prime and oil pressure safety logic included — the factory wire simply stops carrying pump current and becomes a signal wire instead.

From the hanger back, it is a clean replacement. The output connector, the pass-through into the tank, the wiring down to the pump and the pump grounds are all supplied new and sized for a modern high-output pump. Nothing of the factory hanger wiring stays in the current path.

Why this matters

Fuel pump output is a direct function of supply voltage. A pump running a volt or more below battery voltage will not deliver its published flow, and on a boosted or heavily modified engine that shortfall shows up as a lean condition exactly when you can least afford one.

On a C4, voltage is lost in stages: long small-gauge chassis runs, the factory relay and fuse block, the hanger connector, and finally the thin pump leads inside the tank. Each stage is small on its own. Added together, and loaded with a high-output pump drawing several times what the original unit drew, they add up to real pressure loss.

  • Full battery voltage at the pump terminals under load
  • Factory wiring removed from the current path, front and rear
  • Its own fuse, independent of the factory fuse block
  • Factory pump control logic untouched — no safety circuits bypassed

What each part of the kit does

The kit is a system. Each piece exists because the piece it replaces could not carry the current, seal against fuel, or both.

FPWH-044HD — main wiring harness

Battery to the rear of the car

Carries a 10 gauge feed from the battery ring terminal through a sealed 630-series ATC fuse holder, into a 630-series sealed relay with an integral suppression device, and on to the rear of the car in 10 gauge. The factory fuel pump feed plugs into the input side of this harness and does one job: energise the relay coil.

The output is a three-position Metri-Pack 280 connector rated for 30 amps. This is deliberately not the factory hanger connector. The original Weather Pack connector and its terminals were never intended for this kind of current, so the kit supplies its own mating half rather than plugging into one that would become the new weak point.

FPAH-043 — hanger connector adapter

Input side, 1984–1988 only

Corvettes built from 1984 to 1988 use a three-position Weather Pack connector at the hanger; 1989 and later use a four-position. Our harness is standardised on the four-position input, and this adapter converts it to three-position so the kit plugs into an early car with no modification to the vehicle connector. It is included here, and it is the only difference between this kit and the later-car version.

IPH-3W12 — intermediate pump harness

Harness output to the hanger, outside the tank

This is where the kit stops behaving like an ordinary harness. The 10 gauge feed arriving from the relay is split inside the IPH into two bonded 14 gauge conductors, both of which pass through the bulkhead and are recombined on the other side. The pair shares the load in parallel, so the pass-through carries the full circuit current — this is not a step down to a single smaller wire.

It is also where the high-current pump ground is brought back into the circuit. The ground ring terminal on top of the hanger connects into the IPH, where it is bonded to a 10 gauge conductor that carries it forward to a spiked chassis ring terminal at the relay end.

BCA-4W — fuel-safe bulkhead connector assembly

Through the hanger plate

A four-way sealed bulkhead that carries both positive conductors, the low-current ground and the level sender signal through the hanger plate. It seals on the liquid side and the vapour side, so the pass-through is fuel and vapour tight without asking the factory connector to pass current it was never built for.

ITWH-042 — in-tank pump harness

Bulkhead to the pump, inside the tank

Picks up the two positive conductors on the inside of the bulkhead and recombines them into a single feed at the pump. A separate heavy-gauge conductor runs from the pump connector to a ring terminal on the brass bolt that passes through the hanger, forming the high-current ground return.

Built with PTFE or ETFE insulated wire rated to 600 volts — the same wire we use in every in-tank harness we make. It will not swell, harden or leach in gasoline, ethanol blends or methanol. It also carries a flying lead for the fuel level sender, so your factory sender wire joins our harness and its signal passes through the bulkhead to the gauge unchanged.

Fuses, labels and connectors

Supplied in the accessory bag

We no longer ship the fuse holder with a rating printed on it. Customers run a wide range of pumps, and a fixed label on the holder encourages the wrong fuse to be fitted. Instead the kit includes both 25 amp and 30 amp ATC fuses with spares, plus labels so you can mark the holder to match the fuse you actually fit. Insulated butt connectors are included for the small number of joints made to vehicle wiring.

Two grounds, not one

Grounding is where most pump upgrades quietly fail. A pump that cannot get its current back to the chassis is just as starved as one that cannot get current in, and the factory hanger ground path was sized for the original pump.

This kit runs two grounds in parallel, each doing a different job:

High-current groundHeavy-gauge PTFE conductor from the pump connector to a ring terminal on the brass bolt through the hanger. On top of the hanger a second ring terminal picks it up into the IPH, where it bonds to a 10 gauge conductor running forward to a spiked chassis ring terminal at the relay.
Low-current groundCarried through the BCA-4W bulkhead alongside the positive conductors and the sender signal, in parallel with the high-current path.

Follow the grounding instructions exactly. An incomplete ground, or an assumption that the factory ground path still applies, is the single most common cause of a kit that does not perform as expected.

The current path, end to end

Battery ? fuse ? relay10 gauge, sealed 630-series ATC fuse holder, 25A or 30A fuse to suit the pump
Relay630-series sealed relay, triggered by the factory pump feed
Relay ? hanger10 gauge to a three-position Metri-Pack 280 output, rated 30A
Hanger, outsideIPH-3W12 — 10 gauge split into two bonded 14 gauge conductors, high-current ground bonded and carried forward
Through the plateBCA-4W sealed four-way bulkhead, plus the brass bolt for the high-current ground
Hanger, insideITWH-042 — conductors recombined, heavy-gauge ground to the brass bolt, sender pass-through
PumpSumitomo / Tyco open-style connector, no splices, no solder

Engineering specifications

Relay630-series, sealed, integral EMI suppression
Relay socket630-series, push-to-seat
Fuse holder630-series ATC, sealed, supplied unlabelled
Fuses supplied25A and 30A ATC, plus spares and rating labels
Main power feed10 gauge — battery ring terminal to fuse holder, fuse holder to relay, relay to harness output
Bulkhead pass-throughTwo 14 gauge conductors in parallel, 28A combined
Ground return10 gauge to the hanger, heavy-gauge PTFE inside the tank
Harness output connectorMetri-Pack 280, three-position, 30A rated
In-tank wirePTFE / ETFE insulated, 600V rated, submersible
BulkheadBCA-4W, four-way, sealed liquid and vapour side
SplicesUltrasonically welded — no solder joints

Pump compatibility

This kit is for cars running an aftermarket high-output pump. It is not compatible with the factory Delphi pump, which uses a unique 150-series Metri-Pack connector limited to 16 gauge wire — and there would be no benefit in hotwiring a stock pump in any case.

The W in the part number identifies the in-tank pump connector. This kit is supplied with the standard Sumitomo / Tyco open-style connector, which is what these pumps use:

  • Walbro 255 and 350 series
  • Racetronix RXP pumps, 255 and 340 litres per hour
  • Other pumps fitted with the same open-style connector

It is not the right kit for Walbro 450 and 525 pumps. Those are DCSS dual-turbine pumps, and their leads come off the top of the pump head terminating in a 280-series connector. Any pump with 280-series flying leads needs FPWK-043D instead, which is this same kit supplied with a different in-tank harness.

Identifying a 280-series pump lead. The connector body on those leads looks female, but the terminals inside it are male — with Delphi connectors the gender is always named for the terminal, not the body. If your pump has two short leads ending in a two-way connector, it takes the D kit regardless of how the body looks.

Not sure which kit your pump takes? Email [email protected] before ordering and we will confirm it.

Fitment

Vehicle: 1984–1988 Chevrolet Corvette. These years use the three-position Weather Pack hanger connector, and the required adapter is included in this kit.

1989–1996 cars: These use the four-position hanger connector and do not need the adapter — order FPWK-044W (RXP) or FPWK-044D (DCSS).

Installation notes

  • The fuel pump hanger must come out to install the bulkhead connector, the ground bolt and the in-tank harness. Tank lowering, hanger removal and fuel pressure relief are outside the scope of our instructions — follow the factory service manual or an equivalent repair manual for your car.
  • The bulkhead connector and the ground bolt install through the hanger plate and require drilling. Hole sizes and locations are given in the installation manual.
  • Fit the fuse that matches your pump, and apply the corresponding label to the fuse holder so the next person to open it knows what is in there.
  • Work with the battery disconnected and observe normal fuel system safety precautions.

Frequently asked questions

Does my factory fuel pump circuit still need to work?

Yes, and that is by design. The factory circuit triggers our relay, so the factory fuse, relay and wiring must all be functional. If your car has an existing fault in that circuit, fix it first — this kit will not mask it.

Can I use this with the factory pump?

No. The factory Delphi pump uses a unique 150-series Metri-Pack connector that will only accept 16 gauge wire, and our in-tank harness is not built to terminate into it. A stock pump does not draw enough current to benefit from the upgrade anyway. This kit is intended for cars fitted with a high-output aftermarket pump.

Why replace the in-tank wiring as well? Isn't the relay the important part?

The relay fixes the front half of the problem. The hanger connector and the wiring from it down to the pump are sized for the original pump and become the new bottleneck the moment the front half is fixed. Doing both is what makes the voltage gain reach the pump terminals.

Does the fuel level gauge still work?

Yes. The in-tank harness has a flying lead for your factory sender wire, and the signal passes through the bulkhead to the factory circuit unchanged.

Which fuse should I use?

It depends on the pump you are running. Both 25 amp and 30 amp fuses are supplied with spares, and the manual tells you which to fit. Label the holder to match.

Is an installation manual included?

Yes — a full illustrated manual with wiring schematic is supplied with the kit and is also available through the support forum once your access is approved.

I have a question before I order.

Email [email protected]. Our support forum is reserved for customers and access is granted after purchase.

Warranty and technical support

Racetronix products are warranted against defects in materials and workmanship. Technical support is provided to verified customers through our support forum only — we do not provide technical support by phone or email.

Request forum access when you place your order so your account is approved before your parts arrive. Presale questions go to [email protected].

  • Available around the clock, so you are not waiting on business hours
  • Moderated and approval-only — no spam, no noise
  • A searchable knowledge base of real installations going back to 1999
  • Post photos and files without the size limits email imposes
  • Answers stay online, so the next person with your question finds it too

Designed, built and tested by Racetronix in Markham, Ontario, Canada.



Fuel Pump - Hotwire / Upgrade Harnesses

1
FPWH-044HD - C43/C44 Fuel Pump Wiring Harness HD (Qty:1)

Pump Bulkhead Wiring Systems

1
IPH-3W12 - Intermediate Pump Harness WP/MP280 12" (Qty:1)

Bulkhead Connectors

1
BCA-4W - FS Bulkhead Connector Assembly 4-way (Qty:1)

Fuel Pump In-tank Wiring

1
ITWH-042 - In-tank Harness, HD 12", MP1504F»Tyco* (Qty:1)

Butt Connectors (NY)

1
1

Fuel Sender/Module Adapter Harnesses

1
FPAH-043 - WP4M > WP3F C44 to C43 Adapter (Qty:1)
Your Price: $