Universal 4-Wire Fuel Tank Bulkhead Wiring System

Brings four 14 gauge circuits into a fuel tank through a sealed, vapor-proof bulkhead connector. Wire it for up to four pumps, doubled feeds for high-current pumps, or pumps plus a fuel level sender.

Circuits4 x 14 gaugeViolet/grey, black, red, blue
Rating per wire14 A continuous20 A intermittent
In-tank wire16" TeflonGasoline, E85, methanol
Outside harness48" TXLIn nylon loom

Key features

The BCWS-001 brings four wires into a fuel tank through a bulkhead connector that is tested vapor-proof (sealed). The in-tank harness plugs into the bulkhead on the tank side; the outside harness plugs into it on the atmosphere side. Both harnesses have pre-stripped ends, so you cut them to length and terminate them to suit your pumps, sender and vehicle wiring.

  • 4-position bulkhead connector, certified vapor-proof and leak tested
  • Four colour-coded 14 gauge circuits, each rated 14 amps continuous and 20 amps intermittent
  • 16" in-tank harness in Teflon-insulated wire, compatible with gasoline, E85 and methanol
  • 48" outside harness in automotive-grade, oil and gas resistant TXL wire, protected by nylon loom
  • Fits a 10.41 mm (0.410") hole and is held by a one-way stainless locking clip
  • Rebuilds or repairs many early-model metal GM sending units ("pumps on a stick")
  • Wires can be paralleled for high-current pumps or to add reliability

Wiring options

The four circuits can be used in many ways. The chart lists the common layouts; each one has a diagram below. Click an option number to jump to its diagram. Each wire column is one bulkhead circuit, named by its outside (atmosphere) cavity and its tank-side cavity, for example A / E.

OptionLayoutA / E
violet / grey
B / D
black
C / C
red
D / B
blue
Ground studCurrent per pump (continuous, at 20 °C)Level sender ground
1Four pumps, common groundPump 1 +Pump 2 +Pump 3 +Pump 4 +Yes14 A eachNone
2Three pumps + level sender, sender grounded with the pumpsSender signalPump 1 +Pump 2 +Pump 3 +Yes14 A eachGround shared with pumps (stud)
3Two pumps + level sender with its own groundSender signalSender groundPump 1 +Pump 2 +Yes14 A eachDedicated ground through the bulkhead
4Two pumps, doubled feed to eachPump 1 +Pump 1 +Pump 2 +Pump 2 +Yes28 A eachNone
5Staged pumps: primary on one wire, boost on two, + level senderSender signalPump 2 (boost) +Pump 2 (boost) +Pump 1 (primary) +YesPump 1: 14 A; Pump 2: 28 AGround shared with pumps (stud)
6One doubled pump + level sender with its own groundSender signalSender groundPump 1 +Pump 1 +Yes28 ADedicated ground through the bulkhead
7Two pumps, positive and ground for each through the bulkheadPump 1 +Pump 1 groundPump 2 +Pump 2 groundNo14 A eachNone
8One pump, positive and ground both doubledPump 1 +Pump 1 +Pump 1 groundPump 1 groundNo28 ANone
9One pump + level sender, every circuit through the bulkheadSender signalSender groundPump 1 +Pump 1 groundNo14 ADedicated ground through the bulkhead
10One pump + level sender, sender grounded to the pump ground wireSender signalSparePump 1 +Pump 1 groundNo14 AShared with the pump ground wire, in the tank

How the options work:

  • Common ground stud. When all four wires carry power or signals into the tank, the pump grounds go out through a separate brass ground stud in the fuel hat (BHSK-14B under Add-ons, or BHGS-6MSS). The stud carries the combined ground current of every pump on it, so size its outside ground wire for the total.
  • Doubled feeds. Two wires connected together at both ends share the current, so a pair carries up to 28 amps continuous at 20 °C (68 °F), and less when hot (see Current rating and heat). Use a pair for a high-current pump, or for extra reliability.
  • Staged pumps (option 5). A smaller primary pump runs all the time on a single wire. A high-performance boost pump on the doubled wires is switched on only when needed, for example by a relay triggered from a boost pressure switch.
  • Ground through the bulkhead. Without a stud, a pump's ground uses one of the four wires (or two wires paralleled for 28 amps).
  • Level sender ground. A sender can share the pump ground (at the stud, or on the pump ground wire in the tank), or have its own ground wire through the bulkhead. Pump current flowing in a shared ground raises the ground voltage the sender sees, which can make the gauge read off. A dedicated sender ground avoids that, and is the better choice where the vehicle has a separate sender ground circuit.
BCWS-001 wiring option 1: Four pumps, common ground
Option 1. Four pumps, common ground
BCWS-001 wiring option 2: Three pumps + level sender, sender grounded with the pumps
Option 2. Three pumps + level sender, sender grounded with the pumps
BCWS-001 wiring option 3: Two pumps + level sender with its own ground
Option 3. Two pumps + level sender with its own ground
BCWS-001 wiring option 4: Two pumps, doubled feed to each
Option 4. Two pumps, doubled feed to each
BCWS-001 wiring option 5: Staged pumps: primary on one wire, boost on two, + level sender
Option 5. Staged pumps: primary on one wire, boost on two, + level sender
BCWS-001 wiring option 6: One doubled pump + level sender with its own ground
Option 6. One doubled pump + level sender with its own ground
BCWS-001 wiring option 7: Two pumps, positive and ground for each through the bulkhead
Option 7. Two pumps, positive and ground for each through the bulkhead
BCWS-001 wiring option 8: One pump, positive and ground both doubled
Option 8. One pump, positive and ground both doubled
BCWS-001 wiring option 9: One pump + level sender, every circuit through the bulkhead
Option 9. One pump + level sender, every circuit through the bulkhead
BCWS-001 wiring option 10: One pump + level sender, sender grounded to the pump ground wire
Option 10. One pump + level sender, sender grounded to the pump ground wire

Diagrams are block diagrams, not to scale. Letters are the bulkhead cavities: outside letter / tank-side letter (see Bulkhead terminals and wiring). Diagram wire colours show the function (red feed, black ground, violet signal), not the harness colour. Fuses, relays and gauge wiring are not shown; follow your pump and vehicle maker's instructions.

Current rating and heat

The bulkhead uses Metri-Pack 150 terminals. Like every electrical terminal, they carry less current as the temperature around them goes up. The 14 amp rating is for normal temperatures. Under a car on a hot day, next to the exhaust, or in a hot fuel tank, the safe current is lower.

Metri-Pack 150 terminal current derating with temperature

Redrawn from Delphi's derating curve for Metri-Pack 150 tin-plated terminals. Delphi's figures are for a single circuit in free air. With all four circuits loaded, the connector runs hotter, so treat the line as an upper limit.

In plain terms:

  • At room temperature (25 °C / 77 °F), one terminal can take about 19 to 20 amps. The 14 amp rating leaves headroom.
  • At about 80 °C (176 °F), the limit falls to about 14 amps. There is no headroom left.
  • At 100 °C (212 °F), the limit is about 10.5 amps.
  • A terminal run at its limit all the time gets hot, its contact pressure and plating break down, its resistance rises, and it gets hotter still. That is how connectors melt. Do not run these terminals at the edge all the time in hot weather.
  • If a pump is close to 14 amps, or the tank area runs hot, use two wires paralleled for that pump.

Pump guide:

PumpOne wireTwo wires paralleled
RXP 255 (255 lph) and smallerYes. This is the largest pump we recommend on one wire.Yes, for extra margin
340 lph pumps (RXP 340 and similar)Not recommended. It runs at the edge, and long-term reliability is in question.Recommended
Walbro F90000267, F90000274, F90000285 and F90000295NoRequired

Bulkhead terminals and wiring

The bulkhead is lettered differently on each side. The outside (atmosphere) side has cavities A, B, C and D. Inside the tank (vapor side) they come out as E, D, C and B, and the in-tank harness connector carries the same E, B, C, D letters.

Outside (atmosphere) cavityOutside wire colourOutside wire typeTank-side (vapor) cavityIn-tank wire colourIn-tank wire type
AVioletTXL, 14 gaugeEGreyTeflon or Tefzel, 14 gauge
BBlackTXL, 14 gaugeDBlackTeflon or Tefzel, 14 gauge
CRedTXL, 14 gaugeCRedTeflon or Tefzel, 14 gauge
DBlueTXL, 14 gaugeBBlueTeflon or Tefzel, 14 gauge
  • Outside: the cavities take a 4-way Metri-Pack 150.2 connector (RCS-050). The four letters sit in a row, A-B-C-D.
  • Tank (vapor) side: a 4-way Metri-Pack 150 connector (RCS-061). The four letters form a square: E and B on top, D and C below.

Connectors for each end

The harness ends are pre-stripped. These connector sets, under Add-ons, finish them:

PartImageUse it for
RCS-001RCS-001In-tank pump connector (Tyco / Sumitomo style) for regular RXP and GSS-type pumps. Takes one 14 gauge wire on each terminal.
RCS-045RCS-045Same pump connector with larger 12-10 gauge terminals. Use it when you double up wires: two 14 gauge wires fit one terminal.
RCS-095RCS-095Metri-Pack 280 sealed 2-way connector with fuel-resistant fluorosilicone (FVMQ) seals, safe in gasoline and E85. For in-tank pumps supplied with flying leads that end in a Metri-Pack 280 connector: Walbro E85 pumps, and some Aeromotive 340 lph (and a few 255 lph) pumps.
RCS-050RCS-0504-way Metri-Pack 150.2 connector that plugs into the outside (atmosphere) side of the bulkhead.
RCS-061RCS-0614-way Metri-Pack 150 connector for the tank (vapor) side of the bulkhead, if you build your own in-tank harness.
RCS-014RCS-0144-way Weather-Pack connector for the outside harness, so the tank can be unplugged from the vehicle wiring.
BHSK-14BBHSK-14B1/4" brass ground stud kit for a common pump ground through the fuel hat.
BHGS-6MSSBHGS-6MSS6 mm stainless bulkhead ground stud with FKM (Viton) O-ring seals, fuel-tight and vapour-tight. An alternative common ground stud.

Need more circuits or current?

If four 14 gauge circuits are not enough for your application, our 6-way APEX 2.8 bulkhead connectors carry six circuits at up to 30 amps per terminal. They install in a 2" hole and come in four versions:

PartImageDescription
BUNG-BCAPX28ALBUNG-BCAPX28AL6-way (6-circuit) fuel tank bulkhead connector, bolt-in, black anodized 6061-T6 aluminum
BUNG-BCAPX28SSBUNG-BCAPX28SS6-way (6-circuit) fuel tank bulkhead connector, bolt-in, 304 stainless steel
BUNG-BCAPX28WALBUNG-BCAPX28WAL6-way (6-circuit) fuel tank bulkhead connector, weld-in, 6061-T6 aluminum
BUNG-BCAPX28WSSBUNG-BCAPX28WSS6-way (6-circuit) fuel tank bulkhead connector, weld-in, 304 stainless steel

Specifications

Part numberBCWS-001
Circuits4
Wire14 gauge. Outside: violet, black, red, blue. In tank: grey, black, red, blue (see Bulkhead terminals and wiring)
Current rating14 A continuous, 20 A intermittent, per wire, at 20 °C (68 °F). Less when hot; see Current rating and heat.
In-tank harness16" long, Teflon-insulated wire; 4-position connector to the bulkhead at one end, pre-stripped at the other
Fuel compatibility (in-tank)Gasoline, E85, methanol
Outside harness48" long, TXL 14 gauge automotive wire, oil and gas resistant, in nylon loom; pre-stripped at one end
Bulkhead4-position, vapor-proof (sealed), leak tested; retained by a one-way stainless locking clip
Mounting holeØ 10.41 mm (0.410") hole. The alignment notches shown on the drawing are not needed; a drill or punch is fine.
Plate thicknessTested up to 0.1" (2.54 mm)

Tech drawing/schematic

BCWS-001 bulkhead connector drawing and dimensions

Click the drawing for the full PDF with dimensions.

FAQ

Can the bulkhead sit in fuel full time?

Yes. The tank side is designed to be in fuel, and the in-tank harness uses Teflon-insulated wire rated for gasoline, E85 and methanol.

How thick can the tank plate be?

We have tested it on plates up to 0.1" (2.54 mm) thick.

How many pumps can I run?

Up to four at 14 amps each with a common ground stud (option 1). A pump that draws more than 14 amps, or one that runs near 14 amps in a hot location, needs two wires paralleled (options 4, 5, 6 and 8). See the pump guide under Current rating and heat. For a staged setup, with a primary pump that runs all the time and a boost pump that switches on with a relay and pressure switch, see option 5.

Related parts

PartImageDescription
BCA-4WBCA-4WFS Bulkhead Connector Assembly 4-way, the spare bulkhead connector used in this kit
BHGS-6MSSBHGS-6MSSBulkhead ground stud, 6 mm, Viton / stainless
RCS-061RCS-061Connector Set, MP150 4F, ITWH Vapor-Side
RCS-050RCS-050Connector Set, 4-Way MP150.2 (BCA Atmos)
RTY-1-4RTY-1-4Ring Terminal, 1/4" 10-12 Ga.
199-T-6199-T-6Terminal Removal Tool - Narrow

Before you order

  • This is a do-it-yourself part. It assumes you have the skills to wire it. We do not provide support for custom wiring layouts.
  • Check your current. Each wire is rated 14 amps continuous at normal temperatures, and less when hot. An RXP 255 is the largest pump we recommend on one wire. Larger pumps need two wires paralleled.
  • Plan your grounds. If all four wires carry power or signals, add a ground stud (BHSK-14B or BHGS-6MSS).
  • Need more? For more circuits or more current, see the 6-way BUNG-BCAPX28 bulkheads.
© 2026 Racetronix. All rights reserved. | Part No: BCWS-001 | Revision: Alpha