Universal 4-wire fuel tank bulkhead wiring system
$49.00
per EACH (USD)Universal 4-Wire Fuel Tank Bulkhead Wiring System
Brings four 14 gauge circuits into a fuel tank through a sealed, vapor-proof bulkhead connector. Wire it for up to four pumps, doubled feeds for high-current pumps, or pumps plus a fuel level sender.
Key features
The BCWS-001 brings four wires into a fuel tank through a bulkhead connector that is tested vapor-proof (sealed). The in-tank harness plugs into the bulkhead on the tank side; the outside harness plugs into it on the atmosphere side. Both harnesses have pre-stripped ends, so you cut them to length and terminate them to suit your pumps, sender and vehicle wiring.
- 4-position bulkhead connector, certified vapor-proof and leak tested
- Four colour-coded 14 gauge circuits, each rated 14 amps continuous and 20 amps intermittent
- 16" in-tank harness in Teflon-insulated wire, compatible with gasoline, E85 and methanol
- 48" outside harness in automotive-grade, oil and gas resistant TXL wire, protected by nylon loom
- Fits a 10.41 mm (0.410") hole and is held by a one-way stainless locking clip
- Rebuilds or repairs many early-model metal GM sending units ("pumps on a stick")
- Wires can be paralleled for high-current pumps or to add reliability
Wiring options
The four circuits can be used in many ways. The chart lists the common layouts; each one has a diagram below. Click an option number to jump to its diagram. Each wire column is one bulkhead circuit, named by its outside (atmosphere) cavity and its tank-side cavity, for example A / E.
| Option | Layout | A / E violet / grey | B / D black | C / C red | D / B blue | Ground stud | Current per pump (continuous, at 20 °C) | Level sender ground |
|---|---|---|---|---|---|---|---|---|
| 1 | Four pumps, common ground | Pump 1 + | Pump 2 + | Pump 3 + | Pump 4 + | Yes | 14 A each | None |
| 2 | Three pumps + level sender, sender grounded with the pumps | Sender signal | Pump 1 + | Pump 2 + | Pump 3 + | Yes | 14 A each | Ground shared with pumps (stud) |
| 3 | Two pumps + level sender with its own ground | Sender signal | Sender ground | Pump 1 + | Pump 2 + | Yes | 14 A each | Dedicated ground through the bulkhead |
| 4 | Two pumps, doubled feed to each | Pump 1 + | Pump 1 + | Pump 2 + | Pump 2 + | Yes | 28 A each | None |
| 5 | Staged pumps: primary on one wire, boost on two, + level sender | Sender signal | Pump 2 (boost) + | Pump 2 (boost) + | Pump 1 (primary) + | Yes | Pump 1: 14 A; Pump 2: 28 A | Ground shared with pumps (stud) |
| 6 | One doubled pump + level sender with its own ground | Sender signal | Sender ground | Pump 1 + | Pump 1 + | Yes | 28 A | Dedicated ground through the bulkhead |
| 7 | Two pumps, positive and ground for each through the bulkhead | Pump 1 + | Pump 1 ground | Pump 2 + | Pump 2 ground | No | 14 A each | None |
| 8 | One pump, positive and ground both doubled | Pump 1 + | Pump 1 + | Pump 1 ground | Pump 1 ground | No | 28 A | None |
| 9 | One pump + level sender, every circuit through the bulkhead | Sender signal | Sender ground | Pump 1 + | Pump 1 ground | No | 14 A | Dedicated ground through the bulkhead |
| 10 | One pump + level sender, sender grounded to the pump ground wire | Sender signal | Spare | Pump 1 + | Pump 1 ground | No | 14 A | Shared with the pump ground wire, in the tank |
How the options work:
- Common ground stud. When all four wires carry power or signals into the tank, the pump grounds go out through a separate brass ground stud in the fuel hat (BHSK-14B under Add-ons, or BHGS-6MSS). The stud carries the combined ground current of every pump on it, so size its outside ground wire for the total.
- Doubled feeds. Two wires connected together at both ends share the current, so a pair carries up to 28 amps continuous at 20 °C (68 °F), and less when hot (see Current rating and heat). Use a pair for a high-current pump, or for extra reliability.
- Staged pumps (option 5). A smaller primary pump runs all the time on a single wire. A high-performance boost pump on the doubled wires is switched on only when needed, for example by a relay triggered from a boost pressure switch.
- Ground through the bulkhead. Without a stud, a pump's ground uses one of the four wires (or two wires paralleled for 28 amps).
- Level sender ground. A sender can share the pump ground (at the stud, or on the pump ground wire in the tank), or have its own ground wire through the bulkhead. Pump current flowing in a shared ground raises the ground voltage the sender sees, which can make the gauge read off. A dedicated sender ground avoids that, and is the better choice where the vehicle has a separate sender ground circuit.










Diagrams are block diagrams, not to scale. Letters are the bulkhead cavities: outside letter / tank-side letter (see Bulkhead terminals and wiring). Diagram wire colours show the function (red feed, black ground, violet signal), not the harness colour. Fuses, relays and gauge wiring are not shown; follow your pump and vehicle maker's instructions.
Current rating and heat
The bulkhead uses Metri-Pack 150 terminals. Like every electrical terminal, they carry less current as the temperature around them goes up. The 14 amp rating is for normal temperatures. Under a car on a hot day, next to the exhaust, or in a hot fuel tank, the safe current is lower.
Redrawn from Delphi's derating curve for Metri-Pack 150 tin-plated terminals. Delphi's figures are for a single circuit in free air. With all four circuits loaded, the connector runs hotter, so treat the line as an upper limit.
In plain terms:
- At room temperature (25 °C / 77 °F), one terminal can take about 19 to 20 amps. The 14 amp rating leaves headroom.
- At about 80 °C (176 °F), the limit falls to about 14 amps. There is no headroom left.
- At 100 °C (212 °F), the limit is about 10.5 amps.
- A terminal run at its limit all the time gets hot, its contact pressure and plating break down, its resistance rises, and it gets hotter still. That is how connectors melt. Do not run these terminals at the edge all the time in hot weather.
- If a pump is close to 14 amps, or the tank area runs hot, use two wires paralleled for that pump.
Pump guide:
| Pump | One wire | Two wires paralleled |
|---|---|---|
| RXP 255 (255 lph) and smaller | Yes. This is the largest pump we recommend on one wire. | Yes, for extra margin |
| 340 lph pumps (RXP 340 and similar) | Not recommended. It runs at the edge, and long-term reliability is in question. | Recommended |
| Walbro F90000267, F90000274, F90000285 and F90000295 | No | Required |
Bulkhead terminals and wiring
The bulkhead is lettered differently on each side. The outside (atmosphere) side has cavities A, B, C and D. Inside the tank (vapor side) they come out as E, D, C and B, and the in-tank harness connector carries the same E, B, C, D letters.
| Outside (atmosphere) cavity | Outside wire colour | Outside wire type | Tank-side (vapor) cavity | In-tank wire colour | In-tank wire type |
|---|---|---|---|---|---|
| A | Violet | TXL, 14 gauge | E | Grey | Teflon or Tefzel, 14 gauge |
| B | Black | TXL, 14 gauge | D | Black | Teflon or Tefzel, 14 gauge |
| C | Red | TXL, 14 gauge | C | Red | Teflon or Tefzel, 14 gauge |
| D | Blue | TXL, 14 gauge | B | Blue | Teflon or Tefzel, 14 gauge |
Connectors for each end
The harness ends are pre-stripped. These connector sets, under Add-ons, finish them:
| Part | Image | Use it for |
|---|---|---|
| RCS-001 | ![]() | In-tank pump connector (Tyco / Sumitomo style) for regular RXP and GSS-type pumps. Takes one 14 gauge wire on each terminal. |
| RCS-045 | ![]() | Same pump connector with larger 12-10 gauge terminals. Use it when you double up wires: two 14 gauge wires fit one terminal. |
| RCS-095 | ![]() | Metri-Pack 280 sealed 2-way connector with fuel-resistant fluorosilicone (FVMQ) seals, safe in gasoline and E85. For in-tank pumps supplied with flying leads that end in a Metri-Pack 280 connector: Walbro E85 pumps, and some Aeromotive 340 lph (and a few 255 lph) pumps. |
| RCS-050 | ![]() | 4-way Metri-Pack 150.2 connector that plugs into the outside (atmosphere) side of the bulkhead. |
| RCS-061 | ![]() | 4-way Metri-Pack 150 connector for the tank (vapor) side of the bulkhead, if you build your own in-tank harness. |
| RCS-014 | ![]() | 4-way Weather-Pack connector for the outside harness, so the tank can be unplugged from the vehicle wiring. |
| BHSK-14B | ![]() | 1/4" brass ground stud kit for a common pump ground through the fuel hat. |
| BHGS-6MSS | ![]() | 6 mm stainless bulkhead ground stud with FKM (Viton) O-ring seals, fuel-tight and vapour-tight. An alternative common ground stud. |
Need more circuits or current?
If four 14 gauge circuits are not enough for your application, our 6-way APEX 2.8 bulkhead connectors carry six circuits at up to 30 amps per terminal. They install in a 2" hole and come in four versions:
| Part | Image | Description |
|---|---|---|
| BUNG-BCAPX28AL | ![]() | 6-way (6-circuit) fuel tank bulkhead connector, bolt-in, black anodized 6061-T6 aluminum |
| BUNG-BCAPX28SS | ![]() | 6-way (6-circuit) fuel tank bulkhead connector, bolt-in, 304 stainless steel |
| BUNG-BCAPX28WAL | ![]() | 6-way (6-circuit) fuel tank bulkhead connector, weld-in, 6061-T6 aluminum |
| BUNG-BCAPX28WSS | ![]() | 6-way (6-circuit) fuel tank bulkhead connector, weld-in, 304 stainless steel |
Specifications
| Part number | BCWS-001 |
| Circuits | 4 |
| Wire | 14 gauge. Outside: violet, black, red, blue. In tank: grey, black, red, blue (see Bulkhead terminals and wiring) |
| Current rating | 14 A continuous, 20 A intermittent, per wire, at 20 °C (68 °F). Less when hot; see Current rating and heat. |
| In-tank harness | 16" long, Teflon-insulated wire; 4-position connector to the bulkhead at one end, pre-stripped at the other |
| Fuel compatibility (in-tank) | Gasoline, E85, methanol |
| Outside harness | 48" long, TXL 14 gauge automotive wire, oil and gas resistant, in nylon loom; pre-stripped at one end |
| Bulkhead | 4-position, vapor-proof (sealed), leak tested; retained by a one-way stainless locking clip |
| Mounting hole | Ø 10.41 mm (0.410") hole. The alignment notches shown on the drawing are not needed; a drill or punch is fine. |
| Plate thickness | Tested up to 0.1" (2.54 mm) |
FAQ
Can the bulkhead sit in fuel full time?
Yes. The tank side is designed to be in fuel, and the in-tank harness uses Teflon-insulated wire rated for gasoline, E85 and methanol.
How thick can the tank plate be?
We have tested it on plates up to 0.1" (2.54 mm) thick.
How many pumps can I run?
Up to four at 14 amps each with a common ground stud (option 1). A pump that draws more than 14 amps, or one that runs near 14 amps in a hot location, needs two wires paralleled (options 4, 5, 6 and 8). See the pump guide under Current rating and heat. For a staged setup, with a primary pump that runs all the time and a boost pump that switches on with a relay and pressure switch, see option 5.
Related parts
| Part | Image | Description |
|---|---|---|
| BCA-4W | ![]() | FS Bulkhead Connector Assembly 4-way, the spare bulkhead connector used in this kit |
| BHGS-6MSS | ![]() | Bulkhead ground stud, 6 mm, Viton / stainless |
| RCS-061 | ![]() | Connector Set, MP150 4F, ITWH Vapor-Side |
| RCS-050 | ![]() | Connector Set, 4-Way MP150.2 (BCA Atmos) |
| RTY-1-4 | ![]() | Ring Terminal, 1/4" 10-12 Ga. |
| 199-T-6 | ![]() | Terminal Removal Tool - Narrow |
Before you order
- This is a do-it-yourself part. It assumes you have the skills to wire it. We do not provide support for custom wiring layouts.
- Check your current. Each wire is rated 14 amps continuous at normal temperatures, and less when hot. An RXP 255 is the largest pump we recommend on one wire. Larger pumps need two wires paralleled.
- Plan your grounds. If all four wires carry power or signals, add a ground stud (BHSK-14B or BHGS-6MSS).
- Need more? For more circuits or more current, see the 6-way BUNG-BCAPX28 bulkheads.

















.jpg?w=250&h=250)