Relay 630-ISO Shrouded SPDT 60/40A
$10.00
per EACH (USD)630-ISO Sealed Automotive Relay, SPDT (1 Form C), 12 VDC, 40/30 A
Heavy-duty sealed relay with steel mounting bracket and coil suppression resistor, for fuel pumps, fans and other high-current loads.
The Racetronix RY63-65F11-S2 is a 12 volt, single pole double throw (SPDT, 1 Form C) relay in the 630-ISO (mini ISO, 6.3 mm blade) footprint. When the coil is off, terminal 30 is connected to 87a (normally closed). When the coil is energized, 30 switches over to 87 (normally open). That lets one relay turn a load on, turn a load off, or switch power between two circuits.
The relay is sealed against moisture and dirt, with a shroud that latches into a sealed socket and a steel bracket to bolt it down. A 680 ohm resistor across the coil absorbs the voltage spike when the coil turns off, so the relay is safe to drive from an ECU, PCM or other solid-state output. Its contacts are rated well above the 40 A / 30 A printed on top: we mark it lower on purpose, so that it runs well inside its limits and lasts. This is the relay supplied in our RYCS-010 relay and socket kit.
We recommend up to 30 amps continuous and 40 amps intermittent on the normally open contact (87), and up to 30 amps on the normally closed contact (87a). The socket terminals that carry the current derate as the temperature around them rises and with smaller wire: see the terminal derating chart below. Before you choose a load, consider where the relay will be mounted and how hot that spot gets in use: beside the engine or exhaust it can reach about 100°C, where a terminal carries roughly half its room-temperature current.

The relay, with its steel mounting bracket. The terminal diagram and part number are printed on top.
Key features
- SPDT (1 Form C): one normally open (87) and one normally closed (87a) contact, switched from common terminal 30.
- 12 VDC coil with a 680 ohm suppression resistor in parallel: safe with ECU, PCM and other solid-state drivers.
- Marked 40 A normally open / 30 A normally closed; contacts rated 60 A / 45 A at 14 VDC. Recommended: 30 A continuous, 40 A intermittent.
- Sealed, shrouded, with a steel mounting bracket.
- Operating temperature -40°C to 125°C (-40°F to 257°F).
- 6.3 mm (0.250") blades for 630-series high-current sockets and terminals.
- Fits 630-ISO (mini ISO) relay sockets, such as the push-to-seat socket in our RYCS-010 kit.
Terminals: what each one does
The terminal numbers are printed on top of the relay and moulded into its base. These are the standard ISO automotive relay numbers, so they match most wiring diagrams.
| Terminal | Function | Connects to | Typical wire |
|---|---|---|---|
| 30 | Common (switched contact) | Battery positive, through a fuse or circuit breaker sized for the load | Heaviest wire in the circuit (10 or 12 AWG) |
| 87 | Normally open (N.O.) | The load you want turned on when the coil is energized | Same gauge as terminal 30 |
| 87a | Normally closed (N.C.) | The load you want on while the coil is off, or left empty if not used | Sized for its own load |
| 85 | Coil | Switched trigger (positive) or ground; the resistor is not polarity sensitive | Light gauge (18 or 20 AWG; coil draws about 0.15 A) |
| 86 | Coil | The other side of the trigger circuit (ground or positive) | Light gauge (18 or 20 AWG) |
When the coil is off: 30 is connected to 87a. When the coil is energized: 30 is connected to 87, and 87a is open. If you only need an on/off switch, wire 30 and 87 and leave 87a empty.

Looking at the blades. The data sheet in the gallery labels each terminal.
Specifications
General
| Part number | RY63-65F11-S2 |
| Type | 630-ISO (mini ISO) sealed automotive relay |
| Contact form | SPDT, single pole double throw (1 Form C) |
| Cover | Sealed, shrouded, steel mounting bracket |
| Coil suppression | 680 ohm resistor in parallel with the coil |
| Terminals | 6.3 mm (0.250") quick-connect blades |
| Mounting | Terminals down recommended |
| Size | 35.1 x 35.1 mm (1.38" x 1.38") body; mounting bracket hole 6.6 mm (0.26") |
Coil
| Nominal voltage | 12 VDC |
| Must operate voltage | 8.4 VDC maximum |
| Must release voltage | 1.2 VDC minimum |
| Coil resistance | 90 ohms ± 10% |
| Combined resistance with the 680 ohm resistor | 79.5 ohms ± 10% |
| Coil power | 1.8 W |
| Coil current | About 0.15 A at 12 V (calculated) |
Contacts
| Arrangement | SPDT (1 Form C): common 30, normally open 87, normally closed 87a |
| Racetronix rating (marked on the relay) | 40 A normally open, 30 A normally closed, 14 VDC |
| Contact rating (test conditions) | 60 A normally open, 45 A normally closed at 14 VDC |
| Maximum switching power | 840 W |
| Minimum load | 1 A at 6 VDC |
| Contact resistance | 100 milliohms maximum (1 A, 6 VDC) |
| Racetronix recommendation | Up to 30 A continuous, 40 A intermittent (87); up to 30 A (87a) |
Timing, insulation and environment
| Operate time | 10 ms maximum |
| Release time | 10 ms maximum |
| Dielectric strength | 500 VAC, 1 minute, coil to contacts and across open contacts |
| Insulation resistance | 100 megohms minimum at 500 VDC |
| Operating temperature | -40°C to 125°C (-40°F to 257°F) |
| Electrical life | 100,000 operations, resistive load (2 s on, 2 s off) |
| Mechanical life | 1,000,000 operations |
All values at 23°C (73°F) unless stated.
Sockets and related parts
Frequently asked questions
The contacts are rated 60 A. Why is the relay marked 40 A, and why do you recommend 30 A continuous?
A current rating is really a heat rating. Every contact, crimp and terminal has a little resistance, and current through resistance makes heat; the heat goes up with the square of the current, so twice the current makes four times the heat in every connection.
The contacts are rated 60 A (normally open) under test conditions. We mark the relay 40 A / 30 A on purpose, so that in real use it runs well inside its limits and lasts. The current also passes through the socket terminals, whose rating drops with heat and wire size (see below). Up to 30 A continuous and 40 A for short bursts leaves margin for heat, vibration, ageing and a less-than-perfect crimp.
How does temperature change the rating?
Current heats a terminal above the temperature of the air around it, so the hotter the surroundings, the less room is left for heat from current. This is called derating. These are the published curves for 630-series socket terminals:

Left: how far a terminal heats above the surrounding air at a given current. Right: the most current it can carry at a given air temperature. Curves are labelled by wire size in mm².
Read from those curves, approximately, for one terminal in free air:
| Wire on the terminal | 25°C (77°F) | 50°C (122°F) | 75°C (167°F) | 100°C (212°F) |
|---|---|---|---|---|
| 10 AWG (5.0 mm²) | about 50 A | about 46 A | about 36 A | about 24 A |
| 12 AWG (3.0 mm²) | about 40 A | about 35 A | about 27 A | about 18 A |
| 18 AWG (0.8 mm²) | about 20 A | about 17 A | about 14 A | about 10 A |
A relay socket is not one terminal in free air: two or three loaded terminals sit side by side next to the relay coil, which also makes heat. Real limits are lower than the table.
Why does the wire size matter?
The wire is the terminal's heat sink. Copper carries heat as well as current, so heavy wire draws heat away from the terminal and makes less heat of its own. Use 10 AWG wire on 30 and 87 for loads near the top of the range, keep runs short, and make every connection properly: a loose or corroded crimp has extra resistance and becomes a hot spot, a common cause of melted sockets.
Where should I mount the relay?
Somewhere cool and dry. Under the hood beside the engine or exhaust the air can reach about 100°C (212°F), which cuts the current a terminal can carry roughly in half. Inside the car, in the trunk, or under the car away from the exhaust, it stays far cooler. If it has to go under the hood, mount it on the inner fender or firewall away from the exhaust manifolds and turbo, terminals facing down.
Can I trigger it from an ECU or PCM?
Yes. The 680 ohm resistor across the coil absorbs the voltage spike when the coil turns off. The coil draws about 0.15 A at 12 V.
Does coil polarity matter?
No. The suppression is a resistor, not a diode, so 85 and 86 can be wired either way round.
Which socket does it need?
A 630-ISO (mini ISO) socket with 6.3 mm (0.250") terminals. Our RYCS-010 kit has a sealed push-to-seat socket with the terminals, seals and locks for this relay.
Will a 630 relay fit a 280 socket?
No. 630-series relays have wider blades (6.3 mm) than 280-series relays (2.8 mm) and need a 630 socket and terminals. For lighter loads, see our 280-series kits RYCS-001 and RYCS-005.
Is it waterproof?
The relay is sealed against moisture and dust. No IP rating is published, so mount it where it is not sprayed directly or sitting in water, with the terminals facing down.
Does it work on 24 volts?
No. This is a 12 V relay.
Questions and support
Not sure which relay your build needs? Email [email protected] before you order.
Racetronix provides technical support to verified customers through our support forum, not by phone or email. Please request forum access when you place your order so your account is approved before your parts arrive. The forum is moderated, open 24/7, and holds a knowledge base going back to 1999.