Welcome to Racetronix
Welcome to Racetronix  |  All prices indicated are in USD($)  905-477-7014  |   Help   |  Catalogs  |  About Us

Relay Connector Kit (SPDT) MP280S-ISO

Item #: RYCS-005

$13.00

per EACH (USD)
This is an obsolete Item
 
 
 In Stock & Ready to Ship

280-ISO Sealed Relay and Socket Kit, SPDT, 12 V

Epoxy-sealed 12 V relay, weatherproof 5-way Metri-Pack 280 socket, terminals, wire seals and locks: everything to wire one relay. The same parts we use in Racetronix production harnesses.

The Racetronix RYCS-005 is a complete, weatherproof relay kit: one 12 volt 280-ISO (mini ISO) relay, a sealed 5-way Metri-Pack 280 relay socket, the crimp terminals and silicone wire seals for every circuit plus spares, and the locks that hold it all together. It is the same relay and socket used in many Racetronix production harnesses that see dirt, water and under-hood heat.

This kit wires the relay as an SPDT (changeover) relay. The socket has all five terminal positions: 30, 87 and 87a for the load, 85 and 86 for the coil. With the coil off, 30 is connected to 87a (normally closed); with the coil energized, 30 switches to 87 (normally open). That lets one relay turn a load on, turn a load off, or switch power between two circuits.

When the terminals are crimped and seated with their wire seals, the relay and socket make a waterproof seal. The relay itself is also epoxy sealed at the factory, so its silver contacts are protected from corrosion in storage and in use: most relays of this type rely on the socket seal alone. The terminals push in from the back of the socket and can be removed for service.

How much current can this kit carry?

We recommend continuous loads of 20 amps or less, and intermittent loads of no more than 30 amps. The relay contacts are rated to 40 A, but the 280-series socket terminals that carry the current are rated 30 A maximum continuous, and less as the temperature around the socket rises or with smaller wire. A relay kit is only as strong as its weakest link, and here that is the socket. The questions at the bottom of this page explain how heat, wire size, crimping and mounting location affect it. For more than 20 A continuous, such as a high-flow fuel pump or a large electric fan, use one of our 630-series relay kits (RYCS-009 or RYCS-010).

What is in the kit

QtyPartUsed for
112 V 280-ISO relay, SPDT, epoxy sealed, with steel mounting bracket and 680 ohm coil suppression resistor (RY28-65F14-S01)Switching the load
15-way Metri-Pack 280 relay socket, sealed, blackHolds the relay and terminals
4Large female terminals, 10 to 12 gauge wire (3 needed + 1 spare)Terminals 30, 87 and 87a (power and loads)
4Small female terminals, 18 gauge wire (2 needed + 2 spare)Terminals 85 and 86 (coil)
4Blue silicone wire seals (3 needed + 1 spare)Seal the large wires
4Green silicone wire seals (2 needed + 2 spare)Seal the coil wires
1Terminal position lock (TPA), dark greenLocks the terminals in the socket
1Connector position lock (CPA), greenSecondary lock on the socket latch
1#10 x 1/2" Phillips pan head self-tapping screwMounting the relay bracket

Key features

  • Complete kit: relay, sealed socket, terminals and seals for every circuit, with spares.
  • Weatherproof when assembled: silicone wire seals and a sealed socket, plus a factory epoxy-sealed relay.
  • 12 VDC relay with a 680 ohm coil suppression resistor: safe to trigger from an ECU, PCM or other solid-state output, and coil polarity does not matter.
  • Metri-Pack 280 tangless sealed terminals, tin-plated brass, for 10 to 12 gauge load wires and 18 gauge coil wires.
  • Rated -40°C to 125°C (socket and terminals) and -55°C to 125°C (relay): fine under the hood.
  • Steel mounting bracket on the relay; screw included.
  • Recommended for 20 A continuous, 30 A intermittent.

Wiring: what goes where

The terminal numbers are moulded into the relay and the socket. These are the standard ISO relay numbers, so they match most wiring diagrams.

TerminalFunctionConnects toTerminal in kitWire seal
30Common (switched contact)Battery positive, through a fuse sized for the loadLarge (10 to 12 ga)Blue
87Normally openThe load you want turned on when the coil is energizedLarge (10 to 12 ga)Blue
87aNormally closedThe load you want on while the coil is offLarge (10 to 12 ga)Blue
85CoilSwitched trigger (positive) or groundSmall (18 ga)Green
86CoilThe other side of the trigger circuitSmall (18 ga)Green
280-ISO relay dimensions, bottom view and wiring diagram

Relay dimensions in inches [mm], bottom view and wiring diagrams. This kit wires the relay as 1 Form C (SPDT).

Assembling the kit

  1. Slide a wire seal onto each wire before you strip it: blue on the large load wires, green on the coil wires. Small end of the seal toward the end of the wire.
  2. Strip the wire to suit the terminal, then crimp it with an open-barrel crimp tool: the core wings on the bare wire and the insulation wings over the seal, so the seal is held in the terminal.
  3. If you crimped by hand, solder the core wings to the wire, quickly, so the tin plating is not overheated (see the FAQ below). Check the joint: no loose strands, the seal not cut or melted, and the wire cannot pull out.
  4. Push each terminal into the back of the socket in its numbered position until it clicks. Pull back gently to make sure it is locked.
  5. Fit the dark green terminal position lock (TPA) to hold the terminals in place.
  6. Push the relay fully into the socket until the latch engages, then fit the green connector position lock (CPA).
  7. Mount the relay with the screw through its bracket, terminals pointing down if you can, so water cannot sit on the seals.

Terminals can be released from the socket for service. Use new wire seals if the old ones are torn or have been stretched by larger wire.

Specifications

Kit

Part numberRYCS-005
RelayRY28-65F14-S01, 280-ISO, SPDT (1 Form C), 12 VDC
SocketMetri-Pack 280 relay connector, 5-way, sealed, black PA66 nylon
Socket size30.6 mm long x 41.5 mm high x 35.5 mm wide
Terminal lock (TPA)Dark green, PA6 nylon
Connector lock (CPA)Green, polypropylene
Recommended load20 A continuous, 30 A intermittent
Circuits used5 (30, 87, 87a, 85, 86)

Socket terminals (Metri-Pack 280 tangless, sealed)

Large terminals (load)Small terminals (coil)
Wire size3.0 to 5.0 mm² (12 and 10 AWG)0.8 to 1.0 mm² (18 AWG)
MaterialBrass, tin platedBrass, tin plated
Blade size it mates with2.8 x 0.8 mm (0.110")2.8 x 0.8 mm (0.110")
Maximum continuous current (280 system)30 ACoil circuit only (thin stock, lower current)
Wire sealBlue siliconeGreen silicone
Operating temperature-40°C to 125°C
Termination resistanceLess than 10 milliohms (at 20 mV)

The maximum current falls as the temperature around the socket rises and with smaller wire: the 30 A figure is for a single circuit in free air at room temperature. Use 10 gauge wire for loads near the top of the range.

Relay

Contact formSPDT (1 Form C); used as SPST in RYCS-001
Coil12 VDC nominal; must operate 7.2 VDC; maximum continuous 21.0 VDC
Coil resistance124 ohms ± 10%, with a 680 ohm, 1/2 W suppression resistor in parallel (about 105 ohms combined, about 0.11 A at 12 V; calculated)
Maximum switched current (resistive)40 A normally open; 30 A normally closed (relay contacts; the socket limits the kit to 30 A)
Maximum switched power (resistive)420 W normally open; 240 W normally closed
Maximum switched voltage40 VDC
Minimum load5 V, 0.1 A
Contact materialSilver tin oxide; less than 100 milliohms when new
Operate / release time6 ms / 3 ms maximum
Dielectric strength500 Vrms coil to contact and contact to contact
Insulation resistance100 megohms minimum at 500 VDC
Operating temperature-55°C to 125°C (-67°F to 257°F)
Vibration / shock10 to 1000 Hz, 19.8 m/s² / 1000 m/s²
Life10,000,000 operations mechanical; 100,000 at 35 A, 14 VDC resistive
EnclosureP.B.T. polyester, epoxy sealed, shrouded, steel mounting bracket
Relay size1.398" x 1.398" x 1.78" (35.5 x 35.5 x 45.2 mm) including bracket
Weight41 grams
Relay switching ratings by load type at 13.5 VDC

Relay switching ratings by load type. Lamp and motor loads draw a surge when they switch on (make).

Full relay specifications, load ratings by load type and dimensions are on the RY28-65F14-S01 page.

Related parts

  • RY28-65F14-S01: the relay on its own, as a replacement.
  • RYCS-001: the four-way SPST kit, if you only need on/off switching.
  • RYCS-003, RYCS-009, RYCS-010: 630-series relay kits for loads above 20 A continuous. 630-series relays and sockets do not interchange with 280-series parts.

Frequently asked questions

The relay is rated 40 A. Why do you recommend 20 A continuous?

A current rating is really a heat rating. Every contact, crimp and terminal has a tiny electrical resistance, and current flowing through resistance makes heat. The heat goes up with the square of the current: double the current and you get four times the heat in every connection.

The relay's contacts are rated to 40 A (normally open) under test conditions, but the current also has to pass through the socket terminals. The connector maker rates the 280 terminal system at 30 A maximum continuous, and its test figures are for a single terminal in free air on heavy wire. In a real relay socket, two or three loaded terminals sit side by side, right next to a relay coil that runs warm, often under the hood. Each of those things lowers the current a terminal can carry before it overheats.

That is why we recommend 20 A continuous: it leaves margin for heat, vibration, ageing and a less-than-perfect crimp. Up to 30 A intermittent is fine for short bursts, because the parts do not have time to reach full temperature. For more than 20 A continuous, use a 630-series relay and socket (RYCS-009 or RYCS-010), whose larger terminals are rated 46 A.

Current ratings of the 280-ISO relay and socket compared with our recommendation

Our recommendation (dark) against the maximum ratings (red). The kit is limited by the socket terminals, not the relay.

How does temperature change the rating?

The terminals and the socket plastic are rated to 125°C. Current heats the terminal above the temperature of the air around it, so the hotter the surroundings, the less room is left for heat from current. At 125°C ambient there is no room left at all. This is called derating, and the connector maker publishes curves for it.

280 series terminal temperature rise and derating curves by wire size

Left: how far a terminal heats above the air around it at a given current. Right: the most current it can carry at a given air temperature. Curves are labelled by wire size in mm².

Read from those curves, approximately, for one terminal in free air:

Wire on the terminal25°C (77°F)50°C (122°F)75°C (167°F)100°C (212°F)
10 AWG (5.0 mm²)about 42 Aabout 39 Aabout 32 Aabout 20 A
12 AWG (3.0 mm²)about 40 Aabout 36 Aabout 29 Aabout 17 A
18 AWG (0.8 mm²)about 20 Aabout 18 Aabout 15 Aabout 10 A

A relay socket is not one terminal in free air, so real limits are lower than the table. On top of that, the relay's own coil runs about 52°C above the surrounding air when it is energized, and that heat sits right beside the terminals.

Why does the wire size matter?

The wire is the terminal's heat sink. Copper carries heat as well as current, so a heavy wire draws heat away from the crimp and the terminal, and it makes less heat of its own because it has less resistance per foot. The same terminal crimped on 10 gauge wire can carry noticeably more current than on 12 gauge, and much more than on 18 gauge (see the table above).

So: use 10 gauge wire on terminals 30 and 87 for loads near the top of the range, keep long runs as short as you can (long wire also costs voltage at the load), and make every connection properly. A loose, under-crimped or corroded crimp has extra resistance and becomes a hot spot even at moderate current, and it is a common cause of melted relay sockets.

Where should I mount the relay?

Somewhere cool and dry. Under the hood, right beside the engine or exhaust, the air can reach about 100°C (212°F), and at that temperature even a 10 gauge terminal is only good for about 20 A in free air. Inside the car, in the trunk, or under the car away from the exhaust, the air stays far cooler and the same relay and socket have much more headroom.

If it has to go under the hood, mount it on the inner fender or firewall, away from the exhaust manifolds and turbo, with the terminals facing down so water cannot sit on the seals.

How do I crimp the terminals? Do I need to solder them?

Yes, if you are using a hand crimper. These terminals are made to be crimped by a production crimp press, which applies far more pressure than any hand tool. A hand crimp alone will not make a joint tight enough to stay reliable through years of heating and cooling, so after crimping, solder the wire core to the terminal.

Do it quickly: a hot, clean iron with enough power, a little solder on the core wings only, and get off the terminal as soon as the solder flows into the strands. If the iron sits on the terminal too long, it melts or boils the tin plating over the whole terminal, which damages the contact and makes it fail later. Keep solder out of the contact end that grips the relay blade, and do not let it wick up past the insulation wings.

Many people do not have the right iron (temperature and power) or the soldering practice to do this well. If that is you, have the terminals made up by someone who has the right equipment and skills: a bad joint here is the most likely thing to fail.

Can I trigger it from an ECU or PCM?

Yes. The 680 ohm resistor across the coil absorbs the voltage spike when the coil turns off, which protects solid-state outputs. The coil draws about 0.11 A at 12 V.

Does coil polarity matter?

No. The coil suppression is a resistor, not a diode, so 85 and 86 can be wired either way round.

Can I use 16 gauge wire on the coil terminals?

The small terminals in this kit are made for 18 gauge (0.8 to 1.0 mm²) wire. The coil draws only about 0.11 A, so 18 gauge is plenty.

Will it fit my older Racetronix hotwire kit?

Yes, if your kit uses a 280-series relay (part number starting RY28, printed on top of the relay). 630-series relays (RY63) need a 630 socket.

Is it waterproof?

When the terminals are crimped and seated with their seals and the relay is fully latched, the relay and socket seal against water and dirt. No IP rating is published, so mount it terminals down and away from direct spray where you can.

Questions and support

Not sure which relay kit your build needs? Email [email protected] before you order.

Racetronix provides technical support to verified customers through our support forum, not by phone or email. Please request forum access when you place your order so your account is approved before your parts arrive. The forum is moderated, open 24/7, and holds a knowledge base going back to 1999.

© 2026 Racetronix. All rights reserved. | Part No: RYCS-005 | Revision: Alpha
Item #:RYCS-001
$10.00
In Stock
Item #:RYCS-003
$12.99
In Stock