630-ISO Sealed Relay and Push-to-Seat Socket Kit, SPDT, 12 V

Heavy-duty sealed 12 V relay, weatherproof 5-way push-to-seat relay socket, terminals, wire seals and locks: everything to wire one high-current relay.

The Racetronix RYCS-010 is a complete, weatherproof kit for one high-current 630-ISO (mini ISO) relay: a sealed 12 volt SPDT relay, a 5-way push-to-seat relay socket, Metri-Pack 630 crimp terminals and silicone wire seals for every circuit plus spares, and the locks that hold it all together. Use it for loads that are too big for a 280-series relay: high-flow fuel pumps, large electric fans, auxiliary lighting and other heavy circuits.

The relay is single pole, double throw (SPDT). With the coil off, terminal 30 is connected to 87a (normally closed); with the coil energized, 30 switches to 87 (normally open). A 680 ohm resistor across the coil absorbs the voltage spike when the coil turns off, so the relay is safe to drive from an ECU, PCM or other solid-state output. Its contacts are rated well above the 40 A / 30 A printed on top: we mark it lower on purpose, so that it runs well inside its limits and lasts.

The socket is the push-to-seat type: slide the wire seal on, crimp the terminal, and push it into the back of the socket until it clicks. A blue terminal position lock (TPA) then holds every terminal in place. When the terminals are seated with their seals and the relay is latched, the relay and socket seal against water and dirt.

How much current can this kit carry?

We recommend up to 30 amps continuous and 40 amps intermittent on the normally open contact (87), and up to 30 amps on the normally closed contact (87a). The 630-series terminals carry more at room temperature, but their safe current drops as the temperature around the socket rises and with smaller wire: see the terminal derating chart below. Before you choose a load, consider where the relay will be mounted and how hot that spot gets in use: beside the engine or exhaust it can reach about 100°C, where a terminal carries roughly half its room-temperature current. The questions at the bottom of this page explain how heat, wire size, crimping and mounting location affect it.

RYCS-010 relay kit contents: relay, push-to-seat socket, blue TPA, terminals, seals, locks and screw

Everything in the kit. Current production may vary slightly from the photo.

What is in the kit

QtyPartUsed for
112 V 630-ISO relay, SPDT, sealed, with steel mounting bracket and 680 ohm coil suppression resistor (Racetronix RY63-65F11-S2)Switching the load
15-way push-to-seat relay socket, sealed, blackHolds the relay and terminals
1Terminal position lock (TPA), blueLocks the terminals in the socket
5Large Metri-Pack 630 female terminals, 12 to 10 AWG wire (3 needed + 2 spare)Terminals 30, 87 and 87a (power and loads)
3Small Metri-Pack 630 female terminals, 20 to 18 AWG wire (2 needed + 1 spare)Terminals 85 and 86 (coil)
5Blue silicone wire seals (3 needed + 2 spare)Seal the large wires
3Tan silicone wire seals (2 needed + 1 spare)Seal the coil wires
1Cavity plugSeals cavity 87a (normally closed) when you only need on/off switching
1Connector position lock (CPA), greenSecondary lock on the socket latch
1#10 x 1/2" Phillips pan head self-drilling screw, 410 stainless steelMounting the relay bracket
RYCS-010 small parts: terminals, wire seals, CPA, cavity plug and screw

Small parts: 5 large and 3 small terminals, 5 blue and 3 tan wire seals, CPA (dark green), cavity plug (light green) and screw.

Key features

  • Complete kit: relay, sealed push-to-seat socket, terminals and seals for every circuit, with spares.
  • Heavy-duty 630-series terminals (6.3 mm blades) for higher current than 280-series relays and sockets.
  • Relay marked 40 A / 30 A and rated well above that by its maker, for a large safety margin.
  • 680 ohm coil suppression resistor: safe with ECU, PCM and other solid-state drivers; coil polarity does not matter.
  • Push-to-seat socket with blue terminal position lock: terminals push in from the back and lock in.
  • Weatherproof when assembled: sealed relay, silicone wire seals and a sealed socket.
  • Operating temperature -40°C to 125°C (relay, socket and terminals).
  • Steel mounting bracket on the relay; stainless self-drilling screw included.

Wiring: what goes where

The terminal numbers are moulded into the relay and the socket. These are the standard ISO relay numbers, so they match most wiring diagrams.

TerminalFunctionConnects toTerminal in kitWire seal
30Common (switched contact)Battery positive, through a fuse sized for the loadLarge (12 to 10 AWG)Blue
87Normally openThe load you want turned on when the coil is energizedLarge (12 to 10 AWG)Blue
87aNormally closedThe load you want on while the coil is off, or plug the cavity if unusedLarge (12 to 10 AWG)Blue
85CoilSwitched trigger (positive) or groundSmall (20 to 18 AWG)Tan
86CoilThe other side of the trigger circuitSmall (20 to 18 AWG)Tan
Bottom of the RYCS-010 relay socket showing the five terminal cavities

Back of the socket, where the terminals push in. The numbers beside each cavity match the relay.

Assembling the kit

  1. Slide a wire seal onto each wire before you strip it: blue on the large wires (30, 87, 87a), tan on the coil wires (85, 86).
  2. Strip the wire to suit the terminal and crimp it: the core wings on the bare wire and the insulation wings over the seal.
  3. If you crimped by hand, solder the core wings to the wire, quickly, so the tin plating is not overheated (see the questions below). Check the joint: no loose strands, the seal not cut or melted, and the wire cannot pull out.
  4. Push each terminal into the back of the socket in its numbered cavity until it clicks, then pull back gently to check it is locked.
  5. If you are not using the normally closed contact, push the cavity plug into cavity 87a. The coil (85, 86) and common (30) cavities are always used, so 87a is the only one that is ever left empty.
  6. Snap the blue terminal position lock (TPA) into place over the terminals.
  7. Push the relay fully into the socket until it latches, then fit the green connector position lock (CPA).
  8. Mount the relay with the screw through its bracket, terminals facing down if you can.
Blue terminal position lock fitted to the relay socket

The blue terminal position lock (TPA) in place.

Specifications

Kit

Part numberRYCS-010
RelayRacetronix RY63-65F11-S2, 630-ISO, SPDT (1 Form C), 12 VDC, marked 40 A / 30 A
Socket5-way push-to-seat 630-ISO relay socket, sealed; PBT housing, nylon TPA, silicone seals
Socket size38.2 mm x 40.8 mm footprint
Recommended loadUp to 30 A continuous, 40 A intermittent (87); up to 30 A (87a)

Socket terminals (Metri-Pack 630, sealed)

Large terminals (load)Small terminals (coil)
Wire size3.0 to 5.0 mm² (12 and 10 AWG)0.5 to 0.8 mm² (20 and 18 AWG)
MaterialBrass, tin platedBrass, tin plated
Mates with6.3 x 0.8 mm (0.250") blade6.3 x 0.8 mm (0.250") blade
Wire sealBlue silicone, 3.61 to 4.50 mm wire ODTan silicone, 1.65 to 2.40 mm wire OD
Maximum continuous current (630 system)46 A, single circuit in free air at room temperature; less when hot or on smaller wire
Operating temperature-40°C to 125°C

Relay

Contact formSPDT (1 Form C): 30 common, 87 normally open, 87a normally closed
Marking40 A / 30 A, 14 VDC (Racetronix rating, set below the maker rating on purpose)
Maker contact rating60 A normally open, 45 A normally closed at 14 VDC; maximum switching power 840 W
Minimum load1 A at 6 VDC
Contact resistance100 milliohms maximum (1 A, 6 VDC)
Coil12 VDC nominal; operate 8.4 VDC maximum; release 1.2 VDC minimum
Coil resistance90 ohms ± 10%; 79.5 ohms with the 680 ohm suppression resistor in parallel
Coil power / current1.8 W; about 0.15 A at 12 V (calculated)
Operate / release time10 ms / 10 ms maximum
Electrical life100,000 operations, resistive load (2 s on, 2 s off)
Mechanical life1,000,000 operations
Insulation resistance100 megohms minimum at 500 VDC
Dielectric strength500 VAC, 1 minute, coil to contacts and across open contacts
Operating temperature-40°C to 125°C
MountingTerminals down recommended
Size35.1 x 35.1 mm body; mounting bracket hole 6.6 mm
RYCS-010 relay, socket and parts

Relay, socket, TPA and small parts.

Frequently asked questions

The relay is rated 60 A by its maker. Why is it marked 40 A, and why do you recommend 30 A continuous?

A current rating is really a heat rating. Every contact, crimp and terminal has a little resistance, and current through resistance makes heat; the heat goes up with the square of the current, so twice the current makes four times the heat in every connection.

The relay's maker rates its contacts at 60 A (normally open) under test conditions. We mark it 40 A / 30 A on purpose, so that in real use it runs well inside its limits and lasts. The current also passes through the socket terminals, whose rating drops with heat and wire size (see below). Up to 30 A continuous and 40 A for short bursts leaves margin for heat, vibration, ageing and a less-than-perfect crimp.

How does temperature change the rating?

The terminals and socket are rated to 125°C. Current heats a terminal above the temperature of the air around it, so the hotter the surroundings, the less room is left for heat from current. This is called derating, and the connector maker publishes curves for it:

630 series terminal temperature rise and derating curves by wire size

Left: how far a terminal heats above the surrounding air at a given current. Right: the most current it can carry at a given air temperature. Curves are labelled by wire size in mm².

Read from those curves, approximately, for one terminal in free air:

Wire on the terminal25°C (77°F)50°C (122°F)75°C (167°F)100°C (212°F)
10 AWG (5.0 mm²)about 50 Aabout 46 Aabout 36 Aabout 24 A
12 AWG (3.0 mm²)about 40 Aabout 35 Aabout 27 Aabout 18 A
18 AWG (0.8 mm²)about 20 Aabout 17 Aabout 14 Aabout 10 A

A relay socket is not one terminal in free air: two or three loaded terminals sit side by side next to the relay coil, which also makes heat. Real limits are lower than the table.

Why does the wire size matter?

The wire is the terminal's heat sink. Copper carries heat as well as current, so heavy wire draws heat away from the crimp and makes less heat of its own. Use 10 AWG wire on 30 and 87 for loads near the top of the range, keep runs short, and make every connection properly: a loose or corroded crimp has extra resistance and becomes a hot spot, a common cause of melted sockets.

Where should I mount the relay?

Somewhere cool and dry. Under the hood beside the engine or exhaust the air can reach about 100°C (212°F), which cuts the current a terminal can carry roughly in half. Inside the car, in the trunk, or under the car away from the exhaust, it stays far cooler. If it has to go under the hood, mount it on the inner fender or firewall away from the exhaust manifolds and turbo, terminals facing down.

How do I crimp the terminals? Do I need to solder them?

Yes, if you are using a hand crimper. These terminals are made to be crimped by a production press, which applies far more pressure than any hand tool. A hand crimp alone will not stay reliable through years of heating and cooling, so after crimping, solder the wire core to the terminal.

Do it quickly: a hot, clean iron with enough power, a little solder on the core wings only, and get off as soon as the solder flows into the strands. If the iron sits on the terminal too long it melts or boils the tin plating over the whole terminal, which damages the contact and makes it fail later. Keep solder out of the contact end. If you do not have the right iron or the practice, have the terminals made up by someone who does.

Can I trigger it from an ECU or PCM?

Yes. The 680 ohm resistor across the coil absorbs the voltage spike when the coil turns off. The coil draws about 0.15 A at 12 V.

Does coil polarity matter?

No. The suppression is a resistor, not a diode, so 85 and 86 can be wired either way round.

I only need on/off switching. What do I do with 87a?

Leave terminal 87a out and push the cavity plug into cavity 87a so the socket stays sealed. The relay then works as a simple on/off (normally open) relay on 87.

Will a 630 relay fit a 280 socket?

No. 630-series relays have wider blades (6.3 mm) than 280-series relays (2.8 mm) and need a 630 socket and terminals. For lighter loads, see our 280-series kits RYCS-001 and RYCS-005.

Is it waterproof?

When the terminals are crimped and seated with their seals, unused cavities are plugged and the relay is fully latched, the relay and socket seal against water and dirt. No IP rating is published, so mount it terminals down and away from direct spray where you can.

Does it work on 24 volts?

No. This is a 12 V relay.