Welcome to Racetronix
Welcome to Racetronix  |  All prices indicated are in USD($)  905-477-7014  |   Help   |  Catalogs  |  About Us

Techflex Insultherm Tru-Fit Fiberglass Sleeving, 10 AWG, Black

Quick Overview

  • Techflex Insultherm Tru-Fit fiberglass sleeving, 10 AWG size
  • Fits wire or bundle OD 0.102 to 0.112 in (2.6 to 2.8 mm)
  • Braided fiberglass, acrylic treated: low fray, low dust
  • Rated 464 degrees F (240 C); UL VW-1; very high abrasion resistance
  • Sold by the foot; black

Show More
Item #: 299-FGLG.10BK  MPN : FGLG.10-BK

$5.26

per 25 Feet (USD)
This is an obsolete Item
 
 
 In Stock & Ready to Ship

Techflex Insultherm Tru-Fit Fiberglass Sleeving, 10 AWG, Black, Sold by the Foot

Braided fiberglass sleeving, heat treated and acrylic coated so it does not fray or shed: insulates single wires, sensor leads and small lines near heat. UL VW-1.

Techflex Insultherm Tru-Fit braided fiberglass sleeving, black

Techflex Insultherm Tru-Fit is braided fiberglass that has been heat treated and impregnated with an acrylic binder to reduce fraying and dust. Racetronix is a Techflex distributor. It slides over individual wires, thermocouple and sensor leads, soldered joints and small lines to add heat and abrasion protection without bulk. Unlike an expandable braid it hardly stretches: each size fits a narrow range, so match it to what you are covering. This is the 10 AWG size, inside diameter 0.102" to 0.112" (2.6 to 2.8 mm), sold by the foot.

Key features

  • Fiberglass for heat: the maker's catalogue rates Tru-Fit to 464°F (240°C); its data sheet lists the fiberglass to 1,202°F (650°C). Use 464°F as the working limit.
  • UL VW-1 flame rating.
  • Very high abrasion resistance in the maker's test.
  • Acrylic treated: low fraying and dust; flexible down to -94°F (-70°C); resists most organic solvents.
  • Cuts with scissors.

In pictures

Black Tru-Fit fiberglass sleeving over a single red wire
Over a single wire: thin, neat and close-fitting.
Fiberglass sleeving with a frayed cut end beside a cleanly cut end
A cut end left loose can fray (left); tape it before cutting and it stays clean (right).
Black fiberglass sleeving held in a torch flame
Fiberglass does not burn: the sleeving held in a torch flame.

Which size do I need?

Measure the outside diameter of the wire or bundle, insulation included, and choose the size whose inside-diameter range includes it. The AWG sizes are named after the bare wire gauge they match, so an insulated wire usually needs a larger size than its gauge number: measure rather than going by gauge.

PartSizeFits OD fromFits OD toWallWeight per foot
299-FGLG.14BK14 AWG0.064" (1.6 mm)0.072" (1.8 mm)0.011"0.0028 lb
299-FGLG.10BK10 AWG0.102" (2.6 mm)0.112" (2.8 mm)0.011"0.0035 lb
299-FGLG.07BK7 AWG0.144" (3.7 mm)0.158" (4.0 mm)0.013"0.0048 lb
299-FGLG.04BK4 AWG0.204" (5.2 mm)0.224" (5.7 mm)0.016"0.0063 lb
299-FGLG.02BK2 AWG0.258" (6.6 mm)0.278" (7.1 mm)0.016"0.0102 lb
299-FGLG.00BK0 AWG0.325" (8.3 mm)0.347" (8.8 mm)0.016"0.0178 lb
299-FGL0.38BK3/8"0.375" (9.5 mm)0.399" (10.1 mm)0.016"0.0179 lb
299-FGL0.44BK7/16"0.438" (11.1 mm)0.462" (11.7 mm)0.018"0.0204 lb
299-FGL0.50BK1/2"0.500" (12.7 mm)0.524" (13.3 mm)0.018"0.0228 lb
299-FGL0.63BK5/8"0.625" (15.9 mm)0.655" (16.6 mm)0.018"0.0256 lb
299-FGL0.75BK3/4"0.750" (19.0 mm)0.786" (20.0 mm)0.018"0.0416 lb

Sizes are sold by the foot. Pre-cut packs: LOOM-F-10-25 (10 AWG, 25 ft), LOOM-F-2-10 (2 AWG, 10 ft), LOOM-F-3-8-10 (3/8", 10 ft), LOOM-F-4-15 (4 AWG, 15 ft).

Equivalents: other brands' fiberglass sleeving

Shopping for another brand? These are coated fiberglass sleeves in similar sizes. They expand more and are rated differently, so they are near equivalents.

Our partInstead of (brand)Their part numberDescriptionMatch
299-FGL0.38BKHeatshield Products204011 / 204101Hot Rod Sleeve 3/8", 10 ft / 100 ftNear equivalent
299-FGL0.50BKHeatshield Products204012 / 204102Hot Rod Sleeve 1/2", 10 ft / 100 ftNear equivalent
299-FGL0.75BKHeatshield Products204014 / 204104Hot Rod Sleeve 3/4", 10 ft / 100 ftNear equivalent
299-FGLG.00BKHeatshield Products203124Color Sleeve, black, 5/16"-7/16" x 25 ftNear equivalent
299-FGL0.38BKHeatshield Products203124Color Sleeve, black, 5/16"-7/16" x 25 ftNear equivalent
299-FGL0.44BKHeatshield Products203124Color Sleeve, black, 5/16"-7/16" x 25 ftNear equivalent

Other brands' names and part numbers are their owners' trademarks, listed only to help you compare. Check sizes against your application.

Specifications

ConstructionBraided fiberglass, heat treated, acrylic binder
Size10 AWG size
Fits outside diameter0.102" to 0.112" (2.6 to 2.8 mm)
TemperatureCatalogue: 464°F (240°C). Data sheet: fiberglass 1,202°F (650°C) maximum continuous, -94°F (-70°C) minimum
FlammabilityUL VW-1; halogen free
AbrasionVery high (maker's test)
CuttingScissors
Sold asBy the foot, black

Fitting Tru-Fit sleeving

  1. Slide the sleeving over the wire before you crimp or solder the terminal.
  2. Wrap a turn of tape where you will cut, then cut through the tape with scissors to keep the end neat.
  3. Over a soldered joint, center the sleeving over the joint.
  4. Hold the ends with heat shrink or a tie.

Which heat protection do I need?

Heat reaches a hose or wire in three ways, and each needs a different kind of protection.

  • Radiant heat. A header or turbo throws heat out in every direction, like a stove element, and it reaches anything in line of sight. Reflective foil stops it best: the aluminized face bounces it back before it gets in.
  • Heat soak. Hot air and nearby hot parts warm a line slowly and steadily. Insulation stops it. Braided fiberglass traps thousands of tiny pockets of still air, the same way the insulation in a house wall does, and still air carries heat very poorly. Squash the fiberglass and the air goes, and most of the insulation with it.
  • Flame, sparks and splash. A burst line, a backfire or weld spatter. This needs a covering that will not burn: a silicone jacket or a non-flammable fibre.

Foil-over-fiberglass products combine the first two: the foil reflects, the fiberglass insulates. Nothing should rest against a bare header; wrap the header, shield the line, or both.

SituationUseWhy it works
The exhaust itself: headers, down pipes, turbo crossoversHeader wrapKeeps the heat inside the pipe, so far less of it radiates onto the hoses, wiring and bodywork around it. The best fix is usually at the source.
A hose or harness close to a header or turbo (strong radiant heat)T6 ThermaShield split tube or ThermaShield ConvolutedThe aluminized face reflects most of the radiant heat before it gets in, and the fiberglass behind it insulates against what does get through.
A firewall, floor pan, fuel cell or ECU box facing the exhaustThermaShield Flat or ThermaShield WrapThe same foil over fiberglass, as a sheet that sticks on or wraps around odd shapes.
Lines in a hot engine bay: steady heat soak, little direct radiant heatFireFlex fire sleeveA thick layer of fiberglass holds still air, which insulates; the silicone jacket seals out oil, fuel and splash. Leave at least 1/8" of air gap so the fiberglass is never squashed.
Single wires, sensor and thermocouple leads near heatInsultherm Tru-Fit fiberglass sleevingA thin fiberglass braid that insulates without adding bulk.
Plug wire boots close to the headersInsultherm spark plug boot sleevesDouble-thick fiberglass where the boot sits closest to the pipe.
Flame, sparks, weld spatter or molten splashDragon Sleeve, or FireFlex if the line also needs insulatingDragon fibre will not burn and shrugs off sparks, but its thin wall holds little air, so it does not insulate much. FireFlex resists splash and insulates.

All the lines compared:

ProductWhat it isHeat it handlesContinuous ratingHow it fitsBest for
Techflex FireFlex fire sleeveThick fiberglass braid with a silicone jacketDirect heat, open flame, oil and fuel splash500°F (260°C)Slides on before the hose ends go onFuel, oil, brake and clutch lines near headers or turbos
Techflex T6 ThermaShield split tubeAluminized fiberglass tube, split, closes with an adhesive stripReflects radiant heat491°F (255°C) material; reflects radiant heat from a 1,400°F source at 3/8"Wraps around: no need to remove fittingsAssembled hoses and harnesses near exhaust
Techflex ThermaShield ConvolutedSeamless aluminized fiberglass, flexible convoluted tubeReflects radiant heatNot publishedSlides onHoses and wires that bend in several directions
Techflex ThermaShield Flat (full adhesive)Flat aluminized fiberglass with a full adhesive backReflects radiant heatNot publishedSticks to any clean surfaceFirewalls, floor pans, fuel cells, ECU boxes
Techflex ThermaShield Wrap (adhesive edge)Flat aluminized fiberglass joined along one edge by adhesiveReflects radiant heatNot publishedWraps around odd shapesConnectors, sensors, short runs
Techflex Insultherm Tru-Fit fiberglass sleevingAcrylic-treated braided fiberglassDirect heat, no flame or fluid seal464°F (240°C)Slides onIndividual wires, thermocouple and sensor leads
Techflex Insultherm spark plug boot sleevesDouble-thick fiberglass sleeves, 7-1/2" longDirect heat at the header1,200°FSlips over the bootPlug wire boots close to headers
Techflex header wraps: Insultherm, Header Wrap SI, Volcano WrapWoven tape wrapped around the pipeKeeps heat inside the exhaustFiberglass 1,200°F; silica 2,000°F; basalt 1,300°FWrapped with 1/4" overlap, tied at the endsHeaders, down pipes, turbo crossovers
Techflex Dragon SleeveThin double-wall braid of non-flammable Dragon fibreFlame, sparks, weld spatter, molten splash; not an insulatorNone published; the fibre decomposes at 842°F (450°C)Slides on; the braid expandsLines and wires exposed to sparks or open flame
Techflex Weld Wrap HDSilicone-coated silica braid with hook-and-loop closureWeld spatter, slag, sparks; heat500°F (260°C) continuous; 2,000°F (1,093°C) intermittentWraps on with hook-and-loopWelding leads and hoses; lines that see sparks

Frequently asked questions

Why two temperatures, 464°F and 1,202°F?

The fiberglass itself is listed to 1,202°F (650°C), but the catalogue rates the finished sleeving at 464°F (240°C), which covers its acrylic coating and whatever is inside. Plan on 464°F.

What does "10 AWG" mean here?

It is the bare wire gauge the sleeving matches: 10 AWG size fits 0.102" to 0.112". Most insulated wire is larger than its bare gauge, so measure the outside of the wire and use the chart above.

Tru-Fit or FireFlex?

Tru-Fit for single wires and small leads where bulk matters. FireFlex for hoses and larger lines that need a thick insulating layer and a silicone jacket against flame and fluids.

Ratings are the maker's published figures.